Light, Pressure, Temperature, Acceleration, Geomagnetism data Logger
Overview of LoggLaw C7XI(Non-rechargeable model)
The LoggLaw C7XI is an advanced model that builds upon our previous depth-, internal temperature-, external temperature-, and light-sensor loggers (C7 and C8), now featuring additional acceleration and geomagnetic sensors.
In the past, loggers equipped with acceleration and geomagnetic sensors could record data for only a few weeks at most—insufficient for studying the long-term behavior of migratory fish.
The LoggLaw C7XI retains the core strengths of the C7/C8 series, including a high-precision internal clock (±95 seconds per year @ 25 °C) for accurate geolocation. On top of that, it introduces acceleration and geomagnetic sensors capable of long-term, year-scale measurements.
LoggLaw C7XIR(Rechargeable model)
The rechargeable model, LoggLaw C7XIR, offers approximately one-quarter the continuous recording duration of the C7XI, but can be reused repeatedly. Unlike the C7XI, the C7XIR does not come in a stalk-type configuration.
What we can understand with acceleration and geomagnetism :
– Amount of activity (energy consumption)
– Caudal fin frequency (growth)
– Geolocation where illumination does not reach
– Orientation change (navigation)
– Detailed understanding of behavior (feeding, spawning behavior, etc.)

attachment to abdominal cavity of bonito

Logger with stalk
Typical Recording Duration
-18months: Duty Cycle 5 sec (Accelerometer 16Hz, Magnetometer 1Hz), Off Duty 55 sec.
Depth, Internal and external Temp, Light at 60 second interval
| Technical Specification | |||
| Model | LoggLaw C7XI-9D38 | LoggLaw C7XI-9D44 | LoggLaw C7XIR-9D44 |
| Weight in Air | 6.0g (with stalk) | 7.0g (with stalk) | 4.5g (without stalk) |
| Size | φ9 x 38 mm | φ9 x 44 mm | φ9 x 44 mm |
| Absolute Max Depth | 1000m | ||
| Operating Temperature | -5~35℃ | ||
| Real Time Clock Accuracy | Less than ±95 sec / Year (with automatic temperature compensation) | ||
| Memory | 512MB | ||
| Multi-schedule sampling | Yes | ||
| Required Peripherals (Sold Separately) | Adaptor unit Logger Holder& Base Connection cable Micro USB cable Setting Software (LoggLaw Surf) |
||
| Sensors | |||
| Pressure | |||
| -Measurable Depth | 〜600m | ||
| -Accuracy (Temperature range:0…40℃) | ±50cm (@200m depth) | ||
| -Resolution | better than 1cm | ||
| Temperature Sensor | |||
| -Sensor Range | -5〜35℃ | ||
| -Accuracy | ±0.2℃ | ||
| -Resolution | better than 0.05℃ | ||
| Acceletometer | |||
| -Frequency | 4, 8, 16, 32, 64 Hz | ||
| -Sensor Range | ±8 g | ||
| Magnetometer | |||
| -Frequency | 1, 2, 4, 16 Hz | ||
| -Sensor Range | ±1200μT | ||
| Rechargeable | No | No | Yes |
| Battery[1] | 12 months | 18 months | 4.5 months |