Light, Pressure, Temperature, Acceleration, Geomagnetism data Logger

Overview of LoggLaw C7XI(Non-rechargeable model)

The LoggLaw C7XI is an advanced model that builds upon our previous depth-, internal temperature-, external temperature-, and light-sensor loggers (C7 and C8), now featuring additional acceleration and geomagnetic sensors.

In the past, loggers equipped with acceleration and geomagnetic sensors could record data for only a few weeks at most—insufficient for studying the long-term behavior of migratory fish.

The LoggLaw C7XI retains the core strengths of the C7/C8 series, including a high-precision internal clock (±95 seconds per year @ 25 °C) for accurate geolocation. On top of that, it introduces acceleration and geomagnetic sensors capable of long-term, year-scale measurements.

LoggLaw C7XIR(Rechargeable model)

The rechargeable model, LoggLaw C7XIR, offers approximately one-quarter the continuous recording duration of the C7XI, but can be reused repeatedly. Unlike the C7XI, the C7XIR does not come in a stalk-type configuration.

What we can understand with acceleration and geomagnetism :

– Amount of activity (energy consumption)
– Caudal fin frequency (growth)
– Geolocation where illumination does not reach
– Orientation change (navigation)
– Detailed understanding of behavior (feeding, spawning behavior, etc.)

attachment to abdominal cavity of bonito

LoggLawC7

Logger with stalk

Typical Recording Duration
-18months: Duty Cycle 5 sec (Accelerometer 16Hz, Magnetometer 1Hz), Off Duty 55 sec.
Depth, Internal and external Temp, Light at 60 second interval

Technical Specification
ModelLoggLaw C7XI-9D38LoggLaw C7XI-9D44LoggLaw C7XIR-9D44
Weight in Air6.0g
(with stalk)
7.0g
(with stalk)
4.5g
(without stalk)
Sizeφ9 x 38 mm

φ9 x 44 mmφ9 x 44 mm
Absolute Max Depth1000m
Operating Temperature-5~35℃
Real Time Clock AccuracyLess than ±95 sec / Year (with automatic temperature compensation)
Memory512MB
Multi-schedule samplingYes
Required Peripherals
(Sold Separately)
Adaptor unit
Logger Holder& Base
Connection cable
Micro USB cable
Setting Software (LoggLaw Surf)
Sensors
Pressure
-Measurable Depth〜600m
-Accuracy
(Temperature range:0…40℃)
±50cm (@200m depth)
-Resolutionbetter than 1cm
Temperature Sensor
-Sensor Range-5〜35℃
-Accuracy±0.2℃
-Resolutionbetter than 0.05℃
Acceletometer
-Frequency4, 8, 16, 32, 64 Hz
-Sensor Range±8 g
Magnetometer
-Frequency1, 2, 4, 16 Hz
-Sensor Range±1200μT
RechargeableNoNoYes
Battery[1]12 months18 months4.5 months
[1] Depth, Internal and external Temp, Light at 60 second interval